26
SYSTEM DESCRIPTION
Reset
Forces the device restart. The command ensures a com-
plete initialization of all internal electronics and software.
The visual feedback of the operation is returned by the
RESET LED.
Restoring factory
settings
Restores the COMBIVIS connect Router device to factory
settings. All the settings are reset, all the system software is
restored to original versions including the operating system,
thermwaretheCOMBIVISconnectRuntimeandDomain
registrations (identity is removed).
Toexecutetherestore,turnothedevice,pressandhold
down the reset button and give power. You need to hold
down the button for at least 10 seconds. The starting of the
restore process is indicated by the dedicated blink sequence
of the LEDs.
Wait for the process to be completed and system restart.
IN0
This input works as “Connection mode”, also referred as
“selector key” input. By default the status of this input is
ignored. When the COMBIVIS connect Router device is
conguredtohandletheinput(see“Generaloptions”inthe
COMBIVISconnectRouterdevicecongurationchapter)it
can be used to control from outside the connection to the
server. The input can be driven by a mechanical selector, by
a key selector or by PLC outputs.
IN1
This input allows controlling the device restart from outside.
The operation corresponds to the RESET button. Once the
command is received a proper feedback is returned by the
status LED.
OUT0
The output turns active when COMBIVIS connect Router
device is connected to the associated Domain. Note that the
simple connection to the server does not activate the output.
It is required that COMBIVIS connect is successfully authen-
ticated to the Domain.
OUT1
The output is active when at least one Control Center client
is connected to the COMBIVIS connect Router device.
Figure 7: C6 Router L1-L4 features