5
ANTRIEBSTECHNIK
4
35
KEB COMBIVERT F4-F
Name: Basis
15.12.98
4
CP - Parameter
© KEB Antriebstechnik, 1998
All Rights reserved
Operation
Chapter Section PageDate
Enabling of CP-Parameter
Preadjusted CP-parameters are described in the following section.
On delivery all CP-parameters are without password protection, i.e. all changeable
parameters can be readjusted. After the parameterization the unit can be locked
against unauthorized access. The adjusted mode is stored.
4.3.3 Description of CP-
Parameter
Password
FUNC
ENTER
UP
Locking of CP-Parameter
Password input
Direction Actual Resolution
Display of Rotation Motor Speed of Display
"forward" 1837,5 rpm 0,5 rpm
"reverse" 1837,0 rpm 1 rpm
or
1837,5 rpm
Display of the actual motor speed (incremental encoder).
For a correct display value, observe the adjustment of encoder 1 (inc/r) (CP.14) and
the change encoder 1 rotation (CP.34) of the incremental encoder!
Example:
Actual Speed Display
(The internal resolution
of the speed is 0.5 rpm)