6 1
Name: Basis
KEB COMBIVERT F4-F
16
16.03.99
Fucntional Description
© KEB Antriebstechnik, 1999
All Rights reserved
Chapter Section Page Date
Adr.
min max
default
2C04h
1
-
-
FFFF0
Adr.
min max
default
Adr.
min max
default
2C01h
0,1
A
LTK
?0
2C00h
1
hex
-
--
In-Parameter
The software version-number of the Host-CPU and the control hardware is encoded in this parameter.
1. digit: C = F4-F
2. and 3. digit: Software version ( e.g. 14 = 1.4 )
4. digit: Special version ( 0 = Standard)
In. 4 Software version
6.1.5 Description of In-Parameter
In. 0 Inverter type
In. 1 Rated inverter current
Display of rated inverter current in A. The value is determined from the power circuit identification (LTK) and cannot be
changed.
The inverter type is represented as hexadecimal number. The bits have following significance:
hex 1 E D D Display
binary 0001111011011101
bit 0: Voltage class
0 = 230V 1 = 400V
bit 1-5: Unit size
z.B. 01110 = 14
bit 6-8: Control type
000 = 0A.S4 011 = 0C.F4
bit 10: free (default=1)
bit 11-12: Maximal operating frequency
01 = 8kHz 11 = 16kHz
bit 9, 13-15: Housing size
0000 = G 0110 = L
0001 = D 1000 = M
0010 = H 1010 = N
0011 = E 1100 = R
0100 = K 1110 = free