Name: Basis
15.12.98
4
CP - Parameter
© KEB Antriebstechnik, 1998
All Rights reserved
Operation
Chapter Section PageDate
Value Output Variable Value Range when CP.19 = 1
0 Actual speed -2 n
fn
+2 n
fn
= -10V +10V
1 Motor apparent current 0 2 I
SN
=0 +10V
2 Actual torque -2 M
N
+2 M
N
= -10V +10V
3 DC-bus voltage 0 1000 V = 0 +10V
4 Speed reference (CP.6) -2 n
fn
+2 n
fn
= -10V +10V
5 Control difference -2 n
fn
+2 n
fn
= -10V +10V
(speed controller)
6 Set torque -2 M
N
+2 M
N
= -10V +10V
7 Modulation depth 0...100 % ^
=
0 10V
8 Position - in the CP-Mode no funktion-
9 Speed in front of ramp -2 n
fn
+2 n
fn
^
=
-10V +10V
10 REF1 output -10V...+10V ^
=
-10V...+10V
Defines which variable is displayed on analog output 1 (terminal X2.18).
Adjustment Range: 010
Resolution: 1
Factory setting: 2
Customer setting: ________
Note: ENTER-Parameter
Function Output A1
^
^
^
^
^
^
^
During open-loop operation (CP.32 = 0) the analog output A1
has no function with the values 2,5, and 6.
n
fn
: Rated-Rotating Field Speed
M
N
: Rated Torque
I
SN
: Rated-Motor Apparent Current