6 1
Name: Basis
KEB COMBIVERT F4-F
6
16.03.99
Fucntional Description
© KEB Antriebstechnik, 1999
All Rights reserved
Chapter Section Page Date
ru-Parameter
3. Fault signals
The reaction of the drive to the fault signals listed below (abnormal stopping) can be determined with parameter Pn.20
and Pn.23...Pn.26:
Display Bus Meaning
A.EF 90 Abnormal Stopping - The signal for an external fault is given to a programmable digital
input.
(reaction of the drive see parameter Pn.20)
A.buS 93 Abnormal Stopping - The adjusted Watchdog-time (parameter ud.8) of the serial
communication was exceeded.
(reaction of the drive see parameter Pn.23)
A.PrF 94 Abnormal Stopping - At setpoint direction forward terminal F (rotation release forward)
Prohibited Rotation is not active.
Forward (reaction of the drive see parameter Pn.24)
A.Prr 95 Abnormal Stopping - At setpoint direction reverse terminal R (rotation release reverse)
Prohibited Rotation is not active.
Reverse (reaction of the drive see parameter Pn.24)
A.dOH 96 Abnormal Stopping - The temperature monitoring of the motor has tripped and the pre-
Drive Overheat warning time (Pn.16) is active.
(reaction of the drive see parameter Pn.25)
A.OH 99 Abnormal Stopping - The temperature monitoring of the frequency inverter has tripped
Overheat and the prewarning time (10 s) is active.
(reaction of the drive see parameter Pn.26)

Table of Contents

Other manuals for KEB COMBIVERT F4-F

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KEB COMBIVERT F4-F and is the answer not in the manual?

KEB COMBIVERT F4-F Specifications

General IconGeneral
BrandKEB
ModelCOMBIVERT F4-F
CategoryLifting Systems
LanguageEnglish