3.6 Cooling circuit connection
The KeDrive D3-DA device has a capacity of up to 0.5l of coolant depending on the
size. After the disconnection of the connections, liquid may be left in the device and
escape if the device is tipped. We recommend the usage of a self-sealing liquid coupling
(not included in the scope of supply) to prevent the coolant escaping and to make it
possible to disconnect and connect in the lled state.
NOTE:
It is imperative the ow for the liquid cooling is connected to the connection
correspondingly marked in Figure3.9.
1
2
Rücklauf/
return
Vorlauf/
flow
3
4
5
2
flow return
1) Liquid connection with 3/8inch female thread
2) 90°elbow tting with 3/8inch female thread and male thread
3) Self-sealing liquid coupling
4) Self-sealing quick-release connection with hose connection
5) PUR (polyurethane) hose with clip
Note:
Items2 to 5 are not included in the scope
of supply. You will nd these in the cooling
circuit connection set (LCS01). Please order
separately.
Figure 3.10 Example cooling circuit connection
22
1 Mechanical installation
Operation Manual KeDrive D3-DA BG3 and BG4
1804.200B.1-01 Date: 03/2023
Mechanical installation