4.6.1 24 V control supply
The supply units KeDrive D3-DP BG3 and BG4 need an external 24VDC power supply
unit for the 24VDC supply (see Figure 4.9). Details are described in the Operation
Manual KeDrive D3-DP (1804.201B.x). The 24V are distributed to the entire axis group
in the KeDrive D3 system via the busbars.
Figure Key
24 V DC Netzteil
(Power Supply)
1.
2. 3. 4.
X01C
(1) 24 V power supply unit (ext. not
included in the scope of supply)
(2) Controller KeDrive D3-DU
(3) Supply unit
KeDrive D3-DP BG3
(4) Axis controller KeDrive D3-DA BG3
Note:
The 24VDC busbar ttings are to
be tightened to a tightening torque of
1.5Nm.
Figure 4.9 Busbars, 24 V control supply
NOTE:
If an external 24 V supply is used, it must provide safe isolation as per
EN61800-5-1 or EN50178.
4.6.2 Power supply
The supply voltage for the axis controllers is supplied by the supply unit KeDrive D3-DP
via the busbars (DC link). This voltage, also called the DC link voltage, is between
565VDC and 678VDC, depending on the mains supply to the KeDrive D3-DP
(400VAC and 480VAC).
Figure Key
2
C
(
y
(1) DC link jumper
(2) Controller KeDrive D3-DU
(3) Supply unit KeDrive D3-DP BG3
(4) Axis controller KeDrive D3-DABG3
Note:
The DC link busbar ttings are to be tightened to a
tightening torque of 3.0Nm.
Figure 4.10 Busbars, power supply (DC link)
38
1 Electrical installation
Operation Manual KeDrive D3-DA BG3 and BG4
1804.200B.1-01 Date: 03/2023
Electrical installation

Table of Contents