A.3 Power section current data, 24 A to 300 A controller, liquid-cooled
U
Mains
F
S
Unit
D3-DA
320/C-24xx
(BG3)
D3-DA
320/C-32xx
(BG3)
D3-DA
310/C-45xx
(BG3)
D3-DA
320/C-45xx
(BG3)
D3-DA
310/C-80xx
(BG3)
D3-DA
310/C-A3xx
(BG4)
D3-DA
310/C-B1xx
(BG4)
D3-DA
310/C-C0xx
(BG4)
Rated current
230 V /
400 V
2 kHz
A 24.00 32.00 45.00 45.00 80.00 150.00 250.00 300.00
Maximum current A 72.00 96.00 135.00 135.00 240.00 310.00 500.00 630.00
Duration of maximum current ms 500.00 500.00 500.00 500.00 400.00 200.00 200.00 250.00
Overcurrent A 48.00 64.00 90.00 90.00 160.00 250.00 400.00 480.00
Duration of overcurrent s 10.00 10.00 10.00 10.00 10.00 10.00 10.00 10.00
Maximum current for F
M
= 0 Hz A 61.38 81.74 114.98 114.98 195.44 280.00 395.98 500.00
Rated current
230 V /
400 V
4 kHz
A 24.00 32.00 45.00 45.00 80.00 150.00 250.00 300.00
Maximum current A 72.00 96.00 135.00 135.00 240.00 280.00 395.00 525.00
Duration of maximum current ms 300.00 300.00 300.00 300.00 250.00 200.00 200.00 250.00
Overcurrent A 48.00 64.00 90.00 90.00 160.00 200.00 315.00 430.00
Duration of overcurrent s 10.00 10.00 10.00 10.00 10.00 10.00 10.00 10.00
Maximum current for F
M
= 0 Hz A 51.76 69.01 97.02 97.02 164.90 220.00 291.33 375.00
Rated current
230 V /
400 V
8 kHz
A 16.10 21.50 30.20 30.20 53.70 80.00 150.00 190.00
Maximum current A 45.30 60.40 85.00 85.00 144.50 123.87 194.00 380.00
Duration of maximum current ms 500.00 500.00 500.00 500.00 500.00 100.00 100.00 250.00
Overcurrent A 32.20 43.00 60.40 60.40 107.40 123.87 194.00 240.00
Duration of overcurrent s 10.00 10.00 10.00 10.00 10.00 10.00 10.00 10.00
Maximum current for F
M
= 0 Hz A 35.78 47.66 67.03 67.03 113.84 135.11 178.19 185.00
Rated current
230 V /
400 V
12 kHz
A 11.30 15.10 21.20 21.20 37.70 – – –
Maximum current A 34.70 46.20 65.00 65.00 110.50 – – –
Duration of maximum current ms 500.00 500.00 500.00 500.00 500.00 – – –
Overcurrent A 22.60 30.20 42.40 42.40 75.40 – – –
Duration of overcurrent s 10.00 10.00 10.00 10.00 10.00 – – –
Maximum current for F
M
= 0 Hz A 24.04 31.96 44.97 44.97 76.51 – – –
Rated current
230 V /
400 V
16 kHz
A 8.30 11.10 15.60 15.60 27.70 – – –
Maximum current A 26.70 35.60 50.00 50.00 85.00 – – –
Duration of maximum current ms 500.00 500.00 500.00 500.00 500.00 – – –
Overcurrent A 16.60 22.20 31.20 31.20 55.40 – – –
Duration of overcurrent s 10.00 10.00 10.00 10.00 10.00 – – –
Maximum current for F
M
= 0 Hz A 17.54 23.48 32.95 32.95 56.14 – – –
Remarks: Current data per axis in the axis controller 400/480 V AC relate to the feed voltage for the supply unit, rmware release V003.30.00