71
1 Appendix
Operation Manual KeDrive D3-DA BG3 and BG4
1804.200B.1-01 Date: 03/2023
Appendix
U
Mains
F
S
Unit
D3-DA 320/A-24xx
(BG3)
D3-DA 320/A-32xx
(BG3)
D3-DA 310/A-45xx
(BG3)
D3-DA 320/A-45xx
(BG3)
D3-DA 310/A-80xx
(BG3)
D3-DA 310/A-A3xx
(BG4)
D3-DA 310/A-B1xx
(BG4)
Rated current
480 V 2 kHz
A 24.00 32.00 45.00 45.00 80.00 130.00 210.00
Maximum current A 72.00 96.00 135.00 135.00 240.00 268.57 413.00
Duration of maximum current ms 500.00 500.00 500.00 500.00 400.00 200.00 200.00
Overcurrent A 48.00 64.00 90.00 90.00 160.00 185.00 300.00
Duration of overcurrent s 10.00 10.00 10.00 10.00 10.00 10.00 10.00
Maximum current for F
M
= 0 Hz A 56.57 75.38 106.07 106.07 180.17 252.48 356.38
Rated current
480 V 4 kHz
A 24.00 32.00 45.00 45.00 71.70 109.00 175.00
Maximum current A 59.70 79.60 112.00 112.00 215.00 251.28 308.00
Duration of maximum current ms 500.00 500.00 500.00 500.00 250.00 200.00 200.00
Overcurrent A 48.00 64.00 90.00 90.00 143.40 180.00 225.00
Duration of overcurrent s 10.00 10.00 10.00 10.00 10.00 10.00 10.00
Maximum current for F
M
= 0 Hz A 44.26 58.97 83.01 83.01 141.14 185.36 244.66
Rated current
480 V 8 kHz
A 15.20 20.30 28.50 28.50 50.70 54.00 110.00
Maximum current A 37.30 49.80 70.00 70.00 119.00 113.14 175.00
Duration of maximum current ms 500.00 500.00 500.00 500.00 500.00 200.00 200.00
Overcurrent A 30.40 40.60 57.00 57.00 101.40 113.14 135.00
Duration of overcurrent s 10.00 10.00 10.00 10.00 10.00 10.00 10.00
Maximum current for F
M
= 0 Hz A 27.15 36.20 51.05 51.05 86.69 105.67 140.01
Rated current
480 V 12 kHz
A 8.70 11.70 16.40 16.40 29.20 – –
Maximum current A 26.70 35.60 50.00 50.00 85.00 – –
Duration of maximum current ms 500.00 500.00 500.00 500.00 500.00 – –
Overcurrent A 17.40 23.40 32.80 32.80 58.40 – –
Duration of overcurrent s 10.00 10.00 10.00 10.00 10.00 – –
Maximum current for F
M
= 0 Hz A 17.54 23.48 32.95 32.95 56.14 – –
Rated current
480 V 16 kHz
A 6.10 8.20 11.50 11.50 20.40 – –
Maximum current A 19.70 26.30 37.00 37.00 62.90 – –
Duration of maximum current ms 500.00 500.00 500.00 500.00 500.00 – –
Overcurrent A 12.20 16.40 23.00 23.00 40.80 – –
Duration of overcurrent s 10.00 10.00 10.00 10.00 10.00 – –
Maximum current for F
M
= 0 Hz A 12.30 16.40 23.05 23.05 39.17 – –
Remarks: Current data per axis in the axis controller 400/480 V AC refer to the feed voltage for the supply unit, rmware release V003.30.00
Table A.2 Current data, KeDrive D3-DA axis controllers BG3 and BG4, air-cooled