EasyManua.ls Logo

Keba KeDrive D3-DA BG3 - Page 44

Keba KeDrive D3-DA BG3
84 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
U V WU V W
UVW
U
U
VW
U
U
VW
U V W
U
W
W
W
W
W
W
W
W
W
W
W
W
W
W
U
W
UVW
U
VW
U
U
U
Motor 2
3
~
U V WU V W
Holding brake (+)
Holding brake (-)
-
+
-
+
Hiperface DSL+
Hiperface DSL-
H
Motor 1
3
~
Holding brake (+)
Holding brake (-)
Hiperface DSL+
Hiperface DSL-
H
PE
12
Recommended connection
of the motor holding brake
up to max. 2 A brake
current.
The two-wire connection
for the encoder is
connected to connector
HDSL on the "Hiperface
DSL" model (see order
code).
Note:
In preparation and only for
KeDrive D3-DA BG3 up
to 45 A!
Figure 4.15 Connection of two servomotors with Hiperface DSL®
WVU
Holding brake (+)
Holding brake (-)
Motor
3
~
PE
Figure A: Recommended connection of the motor holding brake up to max. 2 A motor brake current.
Figure 4.16 Connection of one servomotor with motor holding brake, KeDrive D3-DA BG4
44
1 Electrical installation
Operation Manual KeDrive D3-DA BG3 and BG4
1804.200B.1-01 Date: 03/2023
Electrical installation

Table of Contents

Related product manuals