EasyManuals Logo

Keithley 2700 Service Manual

Keithley 2700
174 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #12 background imageLoading...
Page #12 background image
List of Illustrations
1 Performance Verification
Figure 1-1 Connections for Model 2700 DC volts verification ................1-8
Figure 1-2 Connections for Model 2700 AC volts verification .................1-9
Figure 1-3 Connections for Model 2700 DC current verification ...........1-11
Figure 1-4 Connections for Model 2700 AC current verification ...........1-12
Figure 1-5 Connections for Model 2700 resistance
verification (100
to 10M
ranges) ...............................1-13
Figure 1-6 Connections for Model 2700 resistance
verification (100M
range) .............................................1-14
Figure 1-7 Connections for Model 2700 frequency verification .............1-17
Figure 1-8 Connections for Model 7700 DC volts verification ..............1-18
Figure 1-9 Connections for Model 7700 AC volts verification ...............1-20
Figure 1-10 Connections for Model 7700 DC current verification ...........1-22
Figure 1-11 Connections for Model 7700 AC current verification ...........1-24
Figure 1-12 Connections for Model 7700 resistance
verification (100
to 10M
ranges) ...............................1-25
Figure 1-13 Connections for Model 7700 resistance
verification (100M
range) .............................................1-26
Figure 1-14 Connections for Model 7700 thermocouple
temperature verification ...................................................1-28
Figure 1-15 Connections for Model 7700 frequency verification .............1-30
Figure 1-16 Connections for Model 7700 ratio and
average verification ..........................................................1-31
2 Calibration
Figure 2-1 Low-thermal short connections ...............................................2-7
Figure 2-2 Connections for DC volts and ohms calibration .....................2-8
Figure 2-3 Connections for DC and AC amps calibration ......................2-10
Figure 2-4 Connections for AC volts calibration ....................................2-11
Figure 2-5 Function generator connections for
manufacturing calibration ................................................2-20
3 Routine Maintenance
Figure 3-1 Power module ..........................................................................3-3
Figure 3-2 Front terminal AMPS fuse ......................................................3-4
Figure 3-3 Model 7700 amps fuses ...........................................................3-5
Figure 3-4 Model 7702 amps fuses ...........................................................3-7
2700ServiceLOF.fm Page 6 Monday, March 13, 2000 11:34 AM

Table of Contents

Other manuals for Keithley 2700

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keithley 2700 and is the answer not in the manual?

Keithley 2700 Specifications

General IconGeneral
TypeDigital Multimeter
Measurement FunctionsDC Voltage, AC Voltage, DC Current, AC Current, Resistance, Frequency, Temperature
DC Voltage Range100 mV to 1000 V
AC Voltage Range100 mV to 750 V
Frequency Range3 Hz to 500 kHz
Temperature Range-200°C to +1372°C
DisplayVacuum Fluorescent Display
ConnectivityIEEE-488, RS-232
Channels10
Power Supply100V to 240V AC, 45Hz to 66Hz
DC Current Range10 µA to 3 A
AC Current Range10 µA to 3 A
Temperature MeasurementThermocouple, RTD

Related product manuals