Dirty and/or poor quality weld
Check that the shielding gas has not run out.
Check that the shielding gas flow is unobstructed.
Check that the gas type is correct for the application.
Check the polarity of the gun/electrode.
Check that the welding procedure is correct for the application.
Varying welding performance
Check that the wire feed mechanism is adjusted properly.
Blow compressed air through the wire liner to check that it is
not blocked.
Check that the wire liner is correct for the selected wire size and
type.
Check the welding gun contact tip's size, type and wear.
Check that the welding gun is not overheating.
Check that the earth return clamp is properly attached to a
clean surface of the workpiece.
High spatter volume
Check the welding parameter values and welding procedure.
Check the gas type and flow.
Check the polarity of the gun/electrode.
Check that the filler wire is correct for the current application.
"Error codes" on the next page
© Kemppi
106
1920960 / 2144

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kemppi X5 FastMig and is the answer not in the manual?

Kemppi X5 FastMig Specifications

General IconGeneral
BrandKemppi
ModelX5 FastMig
CategoryWelding System
LanguageEnglish

Related product manuals