99
99
Function
code
Name
Descriptions
Unit
Factory
setting
Modif.
Setting
range
d0.22
AO1 output
0.0~100.0%
(Ratio of the full range)
0.1%
0.0%
*
0~1000
d0.23
AO2 output
0.0~100.0%
(Ratio of the full range)
0.1%
0.0%
*
0~1000
d0.24
Process close-loop
reference
-100.0~100.0%
(Ratio of the full range)
0.1%
0.0%
*
0~2000
d0.25
Process close-loop
feedback
-100.0~100.0%
(Ratio of the full range)
0.1%
0.05%
*
0~2000
d0.26
Process close-loop
error
-100.0~100.0%
(Ratio of the full range)
0.1%
0.0%
*
0~2000
d0.27
Process close-loop
-100.0~100.0%
(Ratio of the full range)
0.1%
0.0%
*
0~2000
d0.28
Temperature of
heatsink 1
0.0~150.0
0.1℃
0.0
*
0~1500
d0.29
Temperature of
heatsink 2
0.0~150.0
0.1℃
0.0
*
0~1500
d0.30
Total conduction
time
0~65535 hours
1
hours
0
*
0~65535
d0.31
Total operating time
0~65535 hours
1
hours
0
*
0~65535
d0.32
Total fan’s
operating time
0~ 65535 hours
1
hours
0
*
0~65535
d0.33
ASR controller
output
-300.0~300.0%
(Corresponding to drive’s rated
torque)
0.1%
0.0%
*
0~6000
d0.34
Reference torque
-300.0~300.0%
(Corresponding to drive’s rated
torque)
0.1%
0.0%
*
0~6000
d0.35
Zero offset of AI1
0~65535
1
0
*
0~65535
d0.36
Zero offset of AI2
0~65535
1
0
*
0~65535
d0.37
Zero offset of
Keyboard
potentiometer
0~65535
1
0
*
0~65535
d0.38~
d0.39
Reserved
-
-
-
-
-
d0.40
Current count value
0~65535
1
0
*
0~65535
d0.41~
d0.45
Reserved
-
-
-
-
-
Group d1:Fault record
d1.00
Fault record 1
0:No fault records
1:Over-current during
acceleration (E001)
2:Over-current during
deceleration (E002)
3:Over-current in constant speed
operation (E003)
4:Over voltage during
acceleration (E004)
5:Over voltage during
deceleration (E005)
1
0
*
0~50