KINOVA
®
Gen3 Ultra lightweight robot User Guide 147
Safety Most Probable Cause
Maximum torque
Strain gauge improperly soldered
Incorrect torque calibration
Magnetic position
Magnet improperly glued
Hall position
Hall sensor major malfunction
Hall sequence
Hall sensor major malfunction(s)
Input encoder Hall mismatch
Dirt and/or particles on encoder disk
Input encoder index mismatch
Dirt and/or particles on encoder disk
Input encoder magnetic mismatch
Dirt and/or particles on encoder disk
Detached magnet on magnetic encoder
Maximum motor current
Shorted phases
Bad motor
Non-volatile memory corrupted
Incomplete calibration(s
No system information entered
No torque calibration
Motor driver fault
Shorted phases
Hall sensor issue
Watchdog triggered
Firmware issue
Contacting Kinova support
Here's where to turn for related support and advice.
For support and advice on hardware related issues, please don't hesitate to contact us through
the support form on our website:
www.kinovarobotics.com/support.
For development guidance and software-related questions, check out the KINOVA
®
KORTEX™ and KINOVA
®
KORTEX™ ROS GitHub repositories at:
github.com/kinovarobotics/kortex
github.com/kinovarobotics/ros_kortex