5-8
WARMING DRAWER ELEMENT
Refer to page 4-19 for the procedure for servic-
ing the warming drawer element.
1. Unplug range or disconnect power.
2. Disconnect one of the wires from the warm-
ing drawer element terminals.
3. Set the ohmmeter to the R x 1 scale.
4. Touch the ohmmeter test leads to the warm-
ing drawer element terminals. The meter
should indicate between 11 and 23 .
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.