SL-V Series Troubleshooting Guide
Malfunction Indication Comments
26.
Water leaking from the
weep holes in the hard seal
end cap
Damaged high pressure
cylinder
Check for scratches or grooves
on the cone seal surface. If
detected, polish to remove
following the procedure, High
Pressure Cylinder Maintenance,
detailed in Section 9, High
Pressure Water System.
Replace the high pressure
cylinder.
External crack in sealing head Replace the sealing head.
Damaged sealing head Check for scratches or grooves
on the cone seal surface of the
sealing head. If detected, polish
the surface following the
procedure, Sealing Head
Maintenance, detailed in Section
9, High Pressure Water System.
Improper torque on jackbolts Re-torque the jackbolts to the
proper torque specification.