Section 11
Specifications
20413013
8-2012/Rev 10
11-8
Ampacity and Power Voltage Requirements
Power Voltage
Motor
Horsepower Full Load Amps
Circuit Breaker
Amps
460/3/60 100 109 175
575/3/60 100 99 125
11.5 Hydraulic and High Pressure Water System Specifications
Hydraulic System
30 HP 50 HP 60 HP 100 HP
Maximum operating pressure 3,000 psi (207 bar) 2,600 psi (179 bar)
Main system relief valve 3,408 psi (235 bar) 2,973 psi (205 bar)
High Pressure Water System
30 HP 50 HP 60 HP 100 HP
Plunger diameter [inches (mm)] 0.875
(22)
0.875
(22)
0.875
(22)
1.125
(29)
Piston diameter [inches (mm)] 4.03
(102.4)
4.03
(102.4)
4.03
(102.4)
5.50
(139.7)
Intensification ratio 20:1 20:1 20:1 23:1
Maximum flow rate
55,000 psi (3,792 bar)
[gpm (L/min)]
0.60
(2.27)
1.00
(3.79)
1.12
(4.24)
2.00
(7.57)
60,000 psi (4,137 bar)
[gpm (L/min)]
0.52
(1.97)
0.90
(3.41)
1.02
(3.86)
1.88
(7.12)
Minimum outlet pressure 5,800 psi
(400 bar)
5,800 psi
(400 bar)
5,800 psi
(400 bar)
6,700 psi
(462 bar)
Maximum outlet pressure 60,000 psi (4,137 bar)
Pneumatic Control Valve
Maximum water pressure 60,000 psi (4,137 bar)
Minimum air pressure 85 psi (5.9 bar)
Maximum air pressure 100 psi (6.9 bar)
Maximum flow rate 1.0 cfm (0.028) m
3
/min