EasyManua.ls Logo

Kyocera FS-1900 - Interlock Circuit

Kyocera FS-1900
224 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4-33
FS-1900
Interlock circuit
Figure 4-3-11 Interlock system
The interlock circuit is constituted by SW702, the top cover/paper transfer unit interlock, and SW703,
the left cover interlock, both mounted on the sensor board. These switches are controlled by the
actuator which is mechanically activated by the projection on the top cover and the paper transfer
unit. SW703 and SW702 are connected in series to the +24 V power. Physically opening the top
cover, left cover, or the paper transfer unit will disconnect the +24 V power, signaling the status to
the engine board. The top cover switch (SW701) serves only the top cover.
Top cover
Left cover
Sensor board
Left cover
interlock
switch
(SW703)
Top cover/
paper transfer
unit interlock
switch (SW702)
Top cover
switch
(SW701)
Projection
Projection
Projection
Paper transfer unit
Actuator

Table of Contents