2DF
1-3-37
12. Fasten the NCU unit into place from the
bottom with two M3 × 06 chrome binding
screws.
13. Connect the three connectors from the NCU
board to the corresponding connectors on the
fax board, as follows:
Speaker 2-pin connector CN7
NCU board connector CN3
Battery connector CN6
14. Remove the film that fixes the three positive
connectors of the power source PCB from the
optional interface mounting plate.
Important: Dispose of the film that has been
removed.
Figure 1-3-70
Figure 1-3-70-1
NCU unit
Speaker
2-pin connecto
NCU board
M3 × 06 chrome
binding screws
CN7
CN6
CN3
Battery
connector
NCU board
connector
Film
Optional interface
mounting plate