2L6/2N6/2N5/2N4-1
1-4-23
5111 BR eject sensor stay jam BR eject sensor (BRES) does not turn off during paper
feed from cassette 1.
J
5112 BR eject sensor (BRES) does not turn off during paper
feed from cassette 2.
J
5113 BR eject sensor (BRES) does not turn off during paper
feed from cassette 3 (paper feeder/large capacity
feeder).
J
5114 BR eject sensor (BRES) does not turn off during paper
feed from cassette 4 (paper feeder/large capacity
feeder).
J
5115 BR eject sensor (BRES) does not turn off during paper
feed from cassette 5 (side multi tray/side deck).
J
5116 BR eject sensor (BRES) does not turn off during paper
feed from cassette 6 (side paper feeder/side large
capacity feeder).
J
5117 BR eject sensor (BRES) does not turn off during paper
feed from cassette 7 (side paper feeder/side large
capacity feeder).
J
5118 BR eject sensor (BRES) does not turn off during paper
feed from duplex section.
J
5119 BR eject sensor (BRES) does not turn off during paper
feed from MP tray.
J
6000 DF paper entry error DF paper entry sensor (DFPES) turn on before the
eject signal is output from the machine (4000-sheet fin-
isher).
K
6001 DF paper entry sensor (DFPES) turn on before the
eject signal is output from the machine (1000-sheet fin-
isher).
K
6020 DF front cover open DF front upper cover is opened during operation
(4000-sheet finisher).
K
6021 DF front cover is opened during operation (1000-sheet
finisher).
K
6041 DF top cover open DF top cover is opened during operation (1000-sheet
finisher).
K
6050 CF eject cover open CF eject cover is opened during operation (4000-sheet
finisher).
M
6060 MB cover open MB cover is opened during operation (4000-sheet fin-
isher).
L
6070 Center folding unit open Center folding unit is opened during operation (4000-
sheet finisher).
M
6080 CF left guide open CF left guide is opened during operation (4000-sheet
finisher).
M
Code Contents Conditions
Jam