105Expert(t) 2000
TM
Maintenance Manual
Figure 165. Packer Control Selector
5. Make sure the speed-up inhibitor
on the console is set to “Enable”;
6. Turn on the speed-up system
(Bunny button) on the packer
control station: Engine must be
running at 1200 RPM before
checking the pressure (refer to
“Pressure Adjustment Table” on
page 106);
7. Hook a 0-4000 PSI pressure
gauge on the quick connect
located on the hydraulic valve
(Figure 166. “Dump valve” and
Figure 167. “Quick-connect
dump-valve pressure gauge”);
Figure 166. Dump valve
Figure 167. Quick-connect
dump-valve pressure gauge
8. Start the engine, engage the
hydraulic system;
Packer Control
Selector
0-4000 PSI
Gauge
HYJ00910
HYF10195