39Expert(t) 2000
TM
Maintenance Manual
Note:Keep the clean-out traps open
during the cleaning.
Figure 46. Clean-out trap door
10. Clean all accumulated dirt under
the cylinders and in the side
tracks using a hoe and a water
jet if necessary.
11. Clean out the rest of the
Expert(t) 2000
TM
body.
Note:Perform a visual inspection of
the hopper area, checking for
possible leaks in the hydraulic
system and wear on the
mechanical parts.
12. Rake with the hoe small pieces
of garbage out of the clean-out
trap.
13. Clean the area with a water jet.
14. Close the clean-out trap doors.
15. Retract the arm along the
hopper.
Figure 47. Right side control station
16. Open the clean-out trap door on
each side of the hopper (see
Figure 48. “Hopper clean-out
trap door”);
CAUTION
DO NOT USE THE WATER JET DIRECTLY
ON
CONNECTORS OR BATTERY FUSES.
Emergency
Stop Button