20
TROUBLE CAUSE REMEDY
Insu󰀩cient soda ow
(carbonated drinks).
1. Insu󰀩cient CO
2
supply pressure.
2. Shuto󰀨 on mounting block is not fully open.
3. Foreign debris in soda ow control.
1. Verify incoming CO
2
pressure is between
70 PSIG (0.483 MPA) and 80 PSIG (0.552
MPA)
2. Open shuto󰀨 fully.
3. Remove soda ow control from valve and
clean out any foreign material to ensure
smooth spool movement.
Insu󰀩cient water ow (plain
water drinks).
1. Insu󰀩cient incoming supply pressure.
2. Shuto󰀨 on mounting block not fully open.
3. Foreign debris in water ow control.
4. Water ltration problem.
1. Verify incoming supply water pressure to
plain water inlet is a minimum of 50 PSI
(0.345 MPA) and a maximum of 100 PSI
(0.689 MPA).
2. Open shuto󰀨 fully.
3. Remove water ow control from valve and
clean out any foreign material to ensure
smooth spool movement.
4. Service water system as required.
Erratic ratio. 1. Incoming water and/or syrup supply not at
minimum owing pressure.
2. Foreign debris in water and/or syrup ow
control.
3. CO
2
regulator malfunction.
1. Check pressure and adjust.
2. Remove ow control from suspected valve
and clean out any foreign material to
ensure smooth spool movement.
3. Repair or replace CO
2
regulator.
Insu󰀩cient syrup ow. 1. Insu󰀩cient CO
2
pressure to BIB pumps.
2. Shuto󰀨 on mounting block not fully open.
3. Foreign debris in syrup ow control.
4. Defective BIB pump.
1. Adjust CO
2
pressure to BIB pumps to
80 PSI (0.552 MPA) (min. 70 PSI (0.483
MPA). Do not exceed manufacturer’s
recommendations.
2. Open shuto󰀨 fully.
3. Remove syrup ow control from valve and
clean out any foreign material to ensure
smooth spool movement.
4. Replace pump.
Valve will not shut o󰀨. 1. Debris in paddle arms.
2. Solenoid plunger sticking.
1. Activate valve a few times to free debris.
Clean out any foreign material.
2. Replace solenoid coil.
Water continually leaking at
connections.
1. Loose water connections.
2. Flare seal washer leaks.
1. Tighten water connections.
2. Replace are seal washer.