Service Manual JET3
Rev. 1.0 107
6. Turn out the nozzle with the same tool as the retaining plate and clean the nozzle just
like the retaining plate with the special solvent. (Caution: Use the special tool only!)
IMPORTANT: Don´t loose the sealing ring in the Tubus!
Control the right position of the sealing ring!
7. Exhaust the nozzle with compressed air. Put on the compressed air pistol in the middle
of the nozzle and blow out a few seconds. This procedure can be repeated as much as
you like.
8. Fix the nozzle again in the swivel-unit by using the special tool.
Now fix the retaining plate in front of the nozzle. (Caution: Watch out for the mounting
direction!)
sealing ring