5. Pull out the coax connector of the oscillator by using the tweezers. Screw out the
retaining screw of the grounding cable.
6. Remove the retainer of the tubus by screwing out the two torx screws.
7. Push the drop production body to the side slightly and screw out the oscillator with
the special tool. Clean the drop production body afterwards with solvent.