33
111
111=Internal communication
error
Internal communication problem.
A CPU has sent a message, but get no
response from the recipient or the message.
Typical error when a CPU crashes, hangs,
or has been reset. If there no principled
software error and this error occurs more
often might this an indication of a hardware
failure. Cyclone Board defective (unlikely),
5V power supply is unstable or very brief
network drop outs (more likely). Currently
the printer GUI is resetting the system if
such an error appears, to try to get the
system working again.
112
112=Internal communication
error
Internal communication problem.
A CPU has sent a message, but get no
response from the recipient or the message.
Typical error when a CPU crashes, hangs,
or has been reset. If there no principled
software error and this error occurs more
often might this an indication of a hardware
failure. Cyclone Board defective (unlikely),
5V power supply is unstable or very brief
network drop outs (more likely). Currently
the printer GUI is resetting the system if
such an error appears, to try to get the
system working again.
113
113=Internal communication
error
Internal communication problem:
A CPU (RIP) has sent a message (identifier)
to a different CPU which is unknown.
Reboot again the system.
Carry out a software update.
Change the controller-board.
See the service document
"Exchange the Controller board
JET3up"
If no success, please contact
LEIBINGER