Event Component Type - Drive (0x0, 0x1)
Event Specific Data - Optional data is provided with this event.
MEL_DATA_DRIVE_SPFA_STATS
RecoveryFailureType - REC_IMPENDING_DRIVE_FAILURE_RISK_LOW ( impendingDriveFailureLow.html )
MEL_EV_PI_DRIVE_LOCKED_OUT - 0x1020
This event occurs when: An incompatible Protection Information drive has been discovered.
Event Name - PI Drive Locked Out
Event description: Data assurance drive has been locked out
Event Group - Destination Driver
Event Priority - CRITICAL_EVENT
Log Group - Drive (0x2)
Event Category - State (0x5)
Event Component Type - Drive (0x0, 0x1)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - REC_DRIVE_INCOMPATIBLE_PI_TYPE ( driveIncompatiblePIType.html )
MEL_EV_FC_LINK_ERROR_THRESHOLD_CRITICAL - 0x1207
This event occurs when: A Link Error count exceeds the threshold the first time.
Event Name - Link Error Threshold Critical
Event description: Fibre channel link errors - threshold exceeded
Event Group - Fibre Channel Source Driver
Event Priority - CRITICAL_EVENT
Log Group - Controller (0x1)
Event Category - Error (0x1)
Event Component Type - Channel (0x0, 0x6)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - N/A
MEL_EV_FC_SPEED_NEG_FAILURE - 0x1208
This event occurs when: A data rate negotiation fails.
Event Name - FC Speed Neg Failure