RecoveryFailureType - REC_ESM_MISWIRE ( esmMiswire.html )
MEL_EV_DFC_CHANNEL_FAILOVER - 0x1513
This event occurs when: A drive fails.
Event Name - Channel Failover
Event description: Individual drive - Degraded path
Event Group - Fibre Channel-specific Destination Driver
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Error (0x1)
Event Component Type - Channel (0x0, 0x6)
Event Specific Data - Optional data is provided with this event.
MEL_DATA_CHANNEL_LOCATION
RecoveryFailureType - REC_PATH_DEGRADED ( degradedDrivePath.html )
MEL_EV_DFC_HW_FAILED_CHANNEL - 0x1515
This event occurs when: A drive channel hardware fails.
Event Name - Drive Channel Hardware Failed
Event description: Drive Channel hardware failed
Event Group - Fibre Channel-specific Destination Driver
Event Priority - CRITICAL_EVENT
Log Group - Controller (0x1)
Event Category - Error (0x1)
Event Component Type - Channel (0x0, 0x6)
Event Specific Data - Optional data is provided with this event.
MEL_DATA_DDS_RECORD
RecoveryFailureType - N/A
MEL_EV_DFC_LSD_FAILURE - 0x151A
This event occurs when: A drive enclosure attached to a channel port is set to a link speed not supported by
the SFP, resulting in a port bypass. Could also be Are is a faulty SFP, cable, or ESM.
Event Name - Link Speed Detection Failure
Event description: Optical link speed detection failure