Event description: Data rate negotiation failed
Event Group - Fibre Channel Source Driver
Event Priority - CRITICAL_EVENT
Log Group - Controller (0x1)
Event Category - Error (0x1)
Event Component Type - Channel (0x0, 0x6)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - N/A
MEL_EV_DEGRADE_CHANNEL - 0x1209
This event occurs when: A drive channel is set to degraded.
Event Name - Degrade Channel
Event description: Drive channel set to Degraded
Event Group - Fibre Channel Source Driver
Event Priority - CRITICAL_EVENT
Log Group - Controller (0x1)
Event Category - Error (0x1)
Event Component Type - Channel (0x0, 0x6)
Event Specific Data - Optional data is provided with this event.
MEL_DATA_DDS_RECORD
RecoveryFailureType - REC_CHANNEL_DEGRADED ( degradedDriveChannel.html )
MEL_EV_FC_SFP_FAILED - 0x120A
This event occurs when: The SFP on an XBB class controller has failed.
Event Name - SFP Failed
Event description: SFP failed
Event Group - Fibre Channel Source Driver
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Error (0x1)
Event Component Type - Controller SFP (0x2, 0x8)