MEL_DATA_AUTH_DATA
RecoveryFailureType - N/A
MEL_EV_SYMBOL_CONT_SERVICE_MODE - 0x5040
This event occurs when: A controller is placed in service mode.
Event Name - SYMbol Cont Service Mode
Event description: Place controller in service mode
Event Group - SYMbol Server
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Command (0x3)
Event Component Type - Controller (0x0, 0x8)
Event Specific Data - Optional data is provided with this event.
MEL_SYMBOL_DATA_CONTROLLER_NUMBER
RecoveryFailureType - N/A
MEL_EV_LOCK_KEY_VALID_ATTEMPTS_EXCEEDED - 0x506D
This event occurs when: The number of attempts to validate the lock key has exceeded the threshold.
Event Name - Lock Key Failed Validation Attempts Exceeded
Event description: Security (FDE) key failed validation attempts due to excessive tries
Event Group - SYMbol Server
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Command (0x3)
Event Component Type - Controller (0x0, 0x8)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - REC_SECURITY_KEY_VALIDATION_LOCK ( securityKeyValidationLock.html )
MEL_EV_BASE_CONTROLLER_DIAGNOSTIC_FAILED - 0x5100
This event occurs when: One or more diagnostic tests detects that one or more component within the base
controller is not functioning as desired.
Event Name - Base Controller Diagnostic Failed
Event description: Base controller diagnostic failed