Event description: Drive manually failed
Event Group - Configuration Manager
Event Priority - CRITICAL_EVENT
Log Group - Drive (0x2)
Event Category - Notification (0x4)
Event Component Type - Drive (0x0, 0x1)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - N/A
MEL_EV_CFG_DRV_TO_SMALL - 0x2249
This event occurs when: A configuration manager posts an UA/AEN of ASC/ASCQ = 0x3F/0x8B indicating
the controller set the drivestate to Drive Capacity is less than Minimum.
Event Name - CFG Drive Too Small
Event description: Physical drive replacement is too small
Event Group - Configuration Manager
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Drive (0x0, 0x1)
Event Specific Data - Optional data is provided with this event.
MEL_DATA_DRV_REPLACE
RecoveryFailureType - N/A
MEL_EV_WRONG_SECTOR_SIZE - 0x224A
This event occurs when: A configuration manager posts an UA/AEN of ASC/ASCQ = 0x3F/0x8C indicating
the controller set the drive state to Drive has wrong blocksize.
Event Name - Wrong Sector Size
Event description: Drive has wrong block size
Event Group - Configuration Manager
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
212
ThinkSystem DE Series Hardware Installation and Maintenance Guide for 2U Enclosures