EasyManua.ls Logo

Lenovo ThinkSystem DE Series - MEL_EV_DRIVE_UNSUP_INTERPOSER_FW_VER - 0 X2276; MEL_EV_VOLUME_GROUP_INCOMPLETE - 0 X2275

Lenovo ThinkSystem DE Series
292 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Event Group - Configuration Manager
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Volume Group (0x0, 0xE), Disk Pool (0x3, 0x2)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - REC_VOLUME_GROUP_MISSING ( missingVGorDP.html )
MEL_EV_VOLUME_GROUP_INCOMPLETE - 0x2275
This event occurs when: A volume group becomes incomplete because one or more drives in the group have
been removed.
Event Name - Volume Group Incomplete
Event description: Component incomplete
Event Group - Configuration Manager
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Volume Group (0x0, 0xE), Disk Pool (0x3, 0x2)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - REC_VOLUME_GROUP_INCOMPLETE ( incompleteVGorDP.html )
MEL_EV_DRIVE_UNSUP_INTERPOSER_FW_VER - 0x2276
This event occurs when: The firmware version in an interposer is incompatible with the drive behind the
interposer. New interposer firmware is necessary.
Event Name - Interposer FW Version Unsupported
Event description: Interposer FW version unsupported
Event Group - Configuration Manager
Event Priority - CRITICAL_EVENT
Log Group - Drive (0x2)
Event Category - Notification (0x4)
Event Component Type - Drive (0x0, 0x1)