Event Group - Fibre Channel-specific Destination Driver
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Controller (0x0, 0x8)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - N/A
MEL_EV_DFC_CHANNEL_MISWIRE - 0x150F
This event occurs when: Two channels are connected with one or more ESMs in between.
Event Name - Channel Miswire
Event description: Channel miswire
Event Group - Fibre Channel-specific Destination Driver
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Error (0x1)
Event Component Type - Channel (0x0, 0x6)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - N/A
MEL_EV_DFC_ESM_MISWIRE - 0x1510
This event occurs when: Two IOMs (ESMs) of the same tray are seen on the same channel.
Event Name - ESM Miswire
Event description: IOM (ESM) miswire
Event Group - Fibre Channel-specific Destination Driver
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Error (0x1)
Event Component Type - Tray Component (ESM, GBIC/SFP, Power Supply, or Fan) (0x0, 0x7)
Event Specific Data - Optional data is provided with this event.
MEL_SYMBOL_DATA_TRAYNUMBER
Chapter 5. System monitoring 191