Event Name - Reconstruction Drive Failed
Event description: Drive failed - initialization/reconstruction failure
Event Group - Configuration Manager
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Failure (0x2)
Event Component Type - Drive (0x0, 0x1)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - N/A
MEL_EV_LUN_DOWN - 0x2250
This event occurs when: A configuration manager posts an UA/AEN of ASC/ASCQ = 0x3F/0xE0 indicating
Logical Unit Failure.
Event Name - LUN Down
Event description: Volume failure
Event Group - Configuration Manager
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Failure (0x2)
Event Component Type - Volume (0x0, 0xD)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - REC_FAILED_VOLUME ( failedVolume.html )
MEL_EV_CFG_READ_FAIL - 0x2251
This event occurs when: A configuration manager posts an UA/AEN of ASC/ASCQ = 0x3F/0x8E indicating
that the drive failed due to a reconstruction failure at SOD.
Event Name - CFG Read Failure
Event description: Drive failed - reconstruction failure
Event Group - Configuration Manager
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)