MEL_EV_CACHE_MEM_DIAG_FAIL - 0x2110
This event occurs when: A persistent RPA Memory Parity error is detected. A test of the cache memory (the
data buffer on the controller) fails. The test is initiated with the startCacheMemoryDiagnostic_1 SYMbolAPI
command. When the error occurs, the controller logs this event and locks down.
Event Name - Cache Memory Diagnostic Fail
Event description: Controller cache memory initialization failed
Event Group - Cache Manager
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Failure (0x2)
Event Component Type - Controller (0x0, 0x8)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - N/A
MEL_EV_CACHE_BATTERY_WARN - 0x2113
This event occurs when: A cache battery is within the specified number of weeks of failing. The ASC/ASCQ
value of 0x3F/0xD9 is also logged with this event.
Event Name - Cache Battery Warning
Event description: Controller cache battery nearing expiration
Event Group - Cache Manager
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Error (0x1)
Event Component Type - Battery Pack (0x0, 0x9)
Event Specific Data - Optional data is provided with this event.
MEL_DATA_SMART_BATTERY
RecoveryFailureType - REC_BATTERY_NEAR_EXPIRATION ( batteryNearExpiration.html )
MEL_EV_OCB_SETTING_CONFLICT - 0x211B
This event occurs when: A conflict is detected between the NVSRAM setting and the presence of batteries.
Event Name - OCB Setting Conflict
Event description: Batteries present but NVSRAM file configured for no batteries
Event Group - Cache Manager
Chapter 5. System monitoring 207