Event Name - Data Parity Mismatch
Event description: Data/parity mismatch on volume
Event Group - VDD
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Error (0x1)
Event Component Type - Volume (0x0, 0xD)
Event Specific Data - Optional data is provided with this event.
MEL_DATA_PARITY_READ_LBA
RecoveryFailureType - N/A
MEL_EV_MISCORRECTED_DATA - 0x202E
This event occurs when: An Unrecoverable Read Error is detected.
Event Name - Miscorrected Data
Event description: Read drive error during interrupted write
Event Group - VDD
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Controller (0x0, 0x8)
Event Specific Data - Optional data is provided with this event.
MEL_DATA_LBA_INFO
RecoveryFailureType - N/A
MEL_EV_DRIVE_FAIL_READ_ERROR_SCAN_CYCLE - 0x203B
This event occurs when: A drive is failed due to an unrecoverable read error detected during scan cycle.
Event Name - Drive Failure From Un-Recoverable Read Error
Event description: Drive failed due to un-recoverable read error during scan
Event Group - VDD
Event Priority - CRITICAL_EVENT
Log Group - Controller (0x1)