EasyManua.ls Logo

Lenovo ThinkSystem DE Series - MEL_EV_DSAS_EXP_PORT_DEV_MISWIRE - 0 X170 A; MEL_EV_DSAS_WPORT_DEG_TO_FAIL - 0 X1707

Lenovo ThinkSystem DE Series
292 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Error (0x1)
Event Component Type - Tray Component (ESM, GBIC/SFP, Power Supply, or Fan) (0x0, 0x7)
Event Specific Data - Optional data is provided with this event.
MEL_SYMBOL_DATA_SLOTNUMBER
RecoveryFailureType - REC_SAS_PORT_DEGRADED ( failedSASPort.html )
MEL_EV_DSAS_WPORT_DEG_TO_FAIL - 0x1707
This event occurs when: An attached device is determined to be present, but none of the PHYs that
comprise the port attached to that device can connect to or communicate with the device.
Event Name - Degraded Wide Port Becomes Failed
Event description: Degraded wide port becomes failed
Event Group - SAS-Specific Destination Driver
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Error (0x1)
Event Component Type - Tray Component (ESM, GBIC/SFP, Power Supply, or Fan) (0x0, 0x7)
Event Specific Data - Optional data is provided with this event.
MEL_SYMBOL_DATA_SLOTNUMBER
RecoveryFailureType - REC_SAS_PORT_FAILED ( failedSASPort.html )
MEL_EV_DSAS_EXP_PORT_DEV_MISWIRE - 0x170A
This event occurs when: Information not available.
Event Name - DSAS Exp Port Dev Miswire
Event description: Drive expansion port miswire
Event Group - SAS-Specific Destination Driver
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Error (0x1)
Event Component Type - Tray Component (ESM, GBIC/SFP, Power Supply, or Fan) (0x0, 0x7)
Event Specific Data - Optional data is not provided with this event.
198
ThinkSystem DE Series Hardware Installation and Maintenance Guide for 2U Enclosures

Table of Contents

Other manuals for Lenovo ThinkSystem DE Series

Related product manuals