EasyManua.ls Logo

Lenovo ThinkSystem DE Series - MEL_EV_DISCRETE_LINE_FAIL - 0 X2836; MEL_EV_DRIVE_TRAYS_NOT_GROUPED_TOGETHER - 0 X2835; MEL_EV_ICC_REMOVED - 0 X2838

Lenovo ThinkSystem DE Series
292 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - REC_CTL_MISMATCH ( ctrlMismatch.html )
MEL_EV_DRIVE_TRAYS_NOT_GROUPED_TOGETHER - 0x2835
This event occurs when: A storage array configuration requires drive trays to be sequentially cabled together,
but they are not.
Event Name - Drive Trays Not Grouped Together
Event description: Drive trays not cabled correctly
Event Group - Sub System Monitor
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Channel (0x0, 0x6)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - REC_DRIVE_TRAYS_NOT_GROUPED_TOGETHER ( driveTrayCluster.html )
MEL_EV_DISCRETE_LINE_FAIL - 0x2836
This event occurs when: A discrete line test has failed, due to either a fault Controller or a faulty Interconnect
Module.
Event Name - Discrete Line Failure
Event description: Discrete lines diagnostic failure
Event Group - Sub System Monitor
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Controller (0x0, 0x8)
Event Specific Data - Optional data is provided with this event.
MEL_DATA_I2C_VALUE
RecoveryFailureType - REC_FAILED_DISCRETE_LINE ( discreteLineFailed.html )
MEL_EV_ICC_REMOVED - 0x2838
This event occurs when: An interconnect or battery canister is removed from the controller enclosure.
Event Name - Interconnect CRU Removed
Chapter 5. System monitoring 235

Table of Contents

Other manuals for Lenovo ThinkSystem DE Series