CAUTION: 
The power-control button on the device does not turn off the electrical current supplied to the device. 
The device also might have more than one connection to dc power. To remove all electrical current 
from the device, ensure that all connections to dc power are disconnected at the dc power input 
terminals.
To install a hot-swap power supply, complete the following steps:
Watch the procedure
A video of this procedure is available at 
https://www.youtube.com/playlist?list=PLYV5R7hVcs- 
C9jFjZnXQ6AmTXaIdX6_HJ
. 
Step 1.  Touch the static-protective package that contains the new power supply to any unpainted surface 
on the outside of the server. Then, take the power supply out of the package and place it on a 
static-protective surface. 
Step 2.  If the server is in a rack, adjust the cable management arm (CMA) to gain access to the power 
supply bay. 
If you have installed the ThinkSystem 2U CMA Upgrade Kit for Toolless Slide Rail or ThinkSystem 
Toolless Slide Rail Kit with 2U CMA, do the following:
Figure 74. CMA adjustment
a.  Press down the stop bracket  1  and rotate it to the open position.
b.  Rotate the CMA out of the way to gain access to the power supply bay.
100
ThinkSystem SR550 Maintenance Manual