Figure 94. Serial port module installation
Step 3.  Connect the cable of the serial port module to serial-port-module connector on the system board. 
For the location of the serial-port-module connector, see “System board components” on page 27.
After installing the serial port module:  
1.  Complete the parts replacement. See “Complete the parts replacement” on page 164.
2.  To enable the serial port module, do one of the following according to the installed operating system: 
•  For Linux operating system: 
Open the ipmitool and enter the following command to disable the Serial over LAN (SOL) feature:
-I lanplus -H IP -U USERID -P PASSW0RD sol deactivate
•  For Microsoft Windows operating system:
a.  Open the ipmitool and enter the following command to disable the SOL feature:
-I lanplus -H IP -U USERID -P PASSW0RD sol deactivate
b.  Open Windows PowerShell and enter the following command to disable the Emergency 
Management Services (EMS) feature:
Bcdedit /ems no
c.  Restart the server to ensure that the EMS setting takes effect.
System fan replacement
Use this information to remove and install a system fan.
S033 
CAUTION: 
Hazardous energy present. Voltages with hazardous energy might cause heating when shorted with 
metal, which might result in spattered metal, burns, or both. 
Chapter 3. Hardware replacement procedures 119