EasyManua.ls Logo

Lenovo ThinkSystem SR550 - System Fan Replacement

Lenovo ThinkSystem SR550
206 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Figure 94. Serial port module installation
Step 3. Connect the cable of the serial port module to serial-port-module connector on the system board.
For the location of the serial-port-module connector, see “System board components” on page 27.
After installing the serial port module:
1. Complete the parts replacement. See “Complete the parts replacement” on page 164.
2. To enable the serial port module, do one of the following according to the installed operating system:
For Linux operating system:
Open the ipmitool and enter the following command to disable the Serial over LAN (SOL) feature:
-I lanplus -H IP -U USERID -P PASSW0RD sol deactivate
For Microsoft Windows operating system:
a. Open the ipmitool and enter the following command to disable the SOL feature:
-I lanplus -H IP -U USERID -P PASSW0RD sol deactivate
b. Open Windows PowerShell and enter the following command to disable the Emergency
Management Services (EMS) feature:
Bcdedit /ems no
c. Restart the server to ensure that the EMS setting takes effect.
System fan replacement
Use this information to remove and install a system fan.
S033
CAUTION:
Hazardous energy present. Voltages with hazardous energy might cause heating when shorted with
metal, which might result in spattered metal, burns, or both.
Chapter 3. Hardware replacement procedures 119