EasyManua.ls Logo

Lenovo ThinkSystem SR550 - Start Options

Lenovo ThinkSystem SR550
206 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Server models with eight 2.5-inch hot-swap drives
Use this section to understand the cable routing for server models with eight 2.5-inch hot-swap drives.
Note: Both 8i and 16i RAID adapters are supported in this configuration.
Figure 22. Cable routing for server models with eight 2.5-inch hot-swap drives
Cable
From To
1 SAS signal cable* SAS 0 and SAS 1 connectors on the
backplane
HBA/RAID adapter installed in PCIe
slot 4:
Gen 3: C0C1
Gen 4: C0
2 Power cable Power connector on the backplane Backplane power connector 1 on the
system board
Note: *When Gen 4 HBA/RAID adapter is installed, ensure you use Gen 4 SAS signal cable (ThinkSystem
SR550/SR590/SR650 2.5" SAS/SATA/AnyBay 8-Bay X40 RAID Cable Kit).
40 ThinkSystem SR550 Maintenance Manual

Table of Contents

Other manuals for Lenovo ThinkSystem SR550

Related product manuals