Install the M.2 backplane and M.2 drive
Use this information to install the M.2 backplane and M.2 drive.
“Read the  
installation 
Guidelines” on 
page 53
“Power off  
the server  
for this task” 
on page 13
“ATTENTION:  
Static Sensitive Device  
Ground package before opening” 
on page 56
Before installing the M.2 backplane and M.2 drive: 
1.  Touch the static-protective package that contains the new M.2 backplane and M.2 drive to any 
unpainted surface on the outside of the server. Then, take the new M.2 backplane and M.2 drive out of 
the package and place them on a static-protective surface. 
2.  Adjust the retainer on the M.2 backplane to accommodate the particular size of the M.2 drive you wish 
to install. See “Adjust the retainer on the M.2 backplane” on page 140.
3.  Locate the connector on each side of the M.2 backplane. 
Notes: 
•  Some M.2 backplanes support two identical M.2 drives. When two M.2 drives are installed, align and 
support both M.2 drives when sliding the retainer forward to secure the M.2 drives.
•  Install the M.2 drive in slot 0 first.
Figure 107. M.2 drive slot
1  Slot 0
2  Slot 1
To install the M.2 backplane and M.2 drive, complete the following steps:
Watch the procedure
A video of this procedure is available at 
https://www.youtube.com/playlist?list=PLYV5R7hVcs- 
C9jFjZnXQ6AmTXaIdX6_HJ
. 
Chapter 3. Hardware replacement procedures 137