EasyManua.ls Logo

Lenovo x3250 m6 - IMM Events that Automatically Notify Support

Lenovo x3250 m6
696 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Severity
Info
Serviceable
No
Automaticallynotifysupport
No
AlertCategory
Critical-Temperature
SNMPTrapID
0
CIMInformation
Prefix:PLATID:0147
UserResponse
Noaction;informationonly.
IMMEventsthatautomaticallynotifySupport
YoucanconfiguretheLenovoXClarityAdministratorortheCMMtoautomaticallynotifySupport(alsoknown
ascallhome)ifcertaintypesoferrorsareencountered.Ifyouhaveconfiguredthisfunction,seethetablefor
alistofeventsthatautomaticallynotifySupport.
Table28.EventsthatautomaticallynotifySupport
EventIDMessageString
Automatically
NotifySupport
40000086-00000000
TestCallHomeGeneratedbyuser[arg1].
Yes
40000087-00000000
ManualCallHomebyuser[arg1]:[arg2].
Yes
400000cb-00000000TheRAIDcontrollerhasproblemwiththebattery.
Pleasecontacttechnicalsupporttoresolvethis
issue.([arg1],[arg2],[arg3],[arg4],[arg5])
Yes
400000cc-00000000TheRAIDcontrollerdetected
unrecoverableerror.Thecontrollerneeds
replacement.([arg1],[arg2],[arg3],[arg4],[arg5])
Yes
400000d5-00000000
Oneormorevirtualdrivehaveproblem.Please
contacttechnicalsupporttoresolvethis
issue.([arg1],[arg2],[arg3],[arg4],[arg5])
Yes
400000d6-00000000DriveerrorwasdetectedbyRAIDcontroller.
Pleasecontacttechnicalsupporttoresolvethis
issue.([arg1],[arg2],[arg3],[arg4],[arg5])
Yes
80010202-0701ffff
Numericsensor[NumericSensorElementName]goinglow
(lowercritical)hasasserted.(CMOSBattery)
Yes
80010902-0701ffff
Numericsensor[NumericSensorElementName]going
high(uppercritical)hasasserted.(SysBrd12V)
Yes
806f0021-2201ffff
Faultinslot[PhysicalConnectorSystemElementName]on
system[ComputerSystemElementName].(NoOpROM
Space)
Yes
AppendixA.IntegratedManagementModuleII(IMM2)errormessages487