Checkoutprocedure
Thissectionprovidesadditionalinformationforyoutodiagnoseaproblem.
Precautionsbeforeperformingthecheckoutprocedure
Beforeyouperformthecheckoutprocedurefordiagnosinghardwareproblems,reviewthefollowing
information.
Readthesafetyinformation.See“Safety”onpagev.
DynamicSystemAnalysis(DSA)providestheprimarymethodsoftestingthemajorcomponentsofthe
server,suchasthesystemboard,Ethernetcontroller,keyboard,mouse(pointingdevice),serialports,
andharddiskdrives.YoucanalsouseDSAtotestsomeexternaldevices.Ifyouarenotsurewhethera
problemiscausedbythehardwareorbythesoftware,youcanuseDSAtoconfirmthatthehardwareis
workingproperly.
WhenyourunDSA,asingleproblemmightcausemorethanoneerrormessage.Whenthishappens,
correctthecauseofthefirsterrormessage.Theothererrormessagesusuallywillnotoccurthenext
timeyourunDSA.
Important:IfmultipleerrorcodesorlightpathdiagnosticsLEDsindicateamicroprocessorerror,theerror
mightberelatedtothemicroprocessororthemicroprocessorsocket.
BeforeyourunDSA,youmustdeterminewhetherthefailingserverispartofasharedharddiskdrive
cluster(twoormoreserverssharingexternalstoragedevices).Ifitispartofacluster,youcanrunall
diagnosticprogramsexcepttheonesthattestthestorageunit(thatis,aharddiskdriveinthestorage
unit)orthestorageadapterthatisattachedtothestorageunit.Thefailingservermightbepartofa
clusterifanyofthefollowingconditionsistrue:
Youhaveidentifiedthefailingserveraspartofacluster(twoormoreserverssharingexternalstorage
devices).
Oneormoreexternalstorageunitsareattachedtothefailingserverandatleastoneoftheattached
storageunitsisalsoattachedtoanotherserverorunidentifiabledevice.
Oneormoreserversarelocatednearthefailingserver.
Important:IftheserverispartofasharedHDDcluster,runonetestatatime.Donotrunanysuiteof
tests,suchasquick”or“normal”tests,becausethismightenabletheharddiskdrivediagnostictests.
IftheserverishaltedandaPOSTerrorcodeisdisplayed,seeAppendixB“UEFI(POST)errorcodes”on
page491
.Iftheserverishaltedandnoerrormessageisdisplayed,see“Troubleshootingbysymptom”
onpage61and“Solvingundeterminedproblems”onpage72.
Forinformationaboutpower-supplyproblems,see“Solvingpowerproblems”onpage71,“Power
problems”onpage69,and“Power-supplyLEDs”onpage54.
Forintermittentproblems,checktheeventlog;see“Eventlogs”onpage56andAppendixC“DSA
diagnostictestresults”onpage503.
Performingthecheckoutprocedure
Toperformthecheckoutprocedure,dothefollowing:
Step1.Istheserverpartofacluster?
No:GotoStep2onpage50.
Yes:Shutdownallfailingserversthatarerelatedtothecluster.GotoStep3onpage51.
Step2.Dothefollowing:
50LenovoSystemx3250M6InstallationandServiceGuide