Step1.Turnofftheserver.
Step2.Makesurethattheserveriscabledcorrectly.
Step3.Removeordisconnectthefollowingdevices,oneatatime,untilyoufindthefailure.Turnonthe
serverandreconfigureiteachtime.
Anyexternaldevices(suchasprinter,mouse,andnon-Lenovodevices.
Surge-suppressordevice(ontheserver).
Eachadapter.
Harddiskdrives.
Note:Theminimumconfigurationrequiredfortheservertostartisonemicroprocessorandone4
GBDIMM.
Step4.Turnontheserver.Iftheproblemremains,suspectthefollowingcomponentsinthefollowingorder:
1.Powersupply
2.Memory
3.Microprocessor
4.Systemboard
Iftheproblemissolvedwhenyouremoveanadapterfromtheserverbuttheproblemrecurswhenyou
reinstallthesameadapter,suspecttheadapter;iftheproblemrecurswhenyoureplacetheadapterwith
adifferentone,suspecttherisercard.
Ifyoususpectanetworkingproblemandtheserverpassesallthesystemtests,suspectanetworkcabling
problemthatisexternaltotheserver.
Problemdeterminationtips
Becauseofthevarietyofhardwareandsoftwarecombinationsthatcanencounter,usethefollowing
informationtoassistyouinproblemdetermination.Ifpossible,havethisinformationavailablewhen
requestingassistancefromLenovo.
ThemodelnumberandserialnumberoftheserverareontheIDlabelattachedonthefrontbezel.
Figure13.IDlabelonthefrontoftheserver
Machinetypeandmodel
Microprocessororharddiskdriveupgrades
Failuresymptom
Doestheserverfailthediagnostictests?
Whatoccurs?When?Where?
Doesthefailureoccuronasingleserveroronmultipleservers?