EasyManua.ls Logo

Lenovo x3250 m6 - Page 667

Lenovo x3250 m6
696 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
IBMSupportwebsite
LatestlevelofDSA
LatestlevelofBMC/IMM
166-904-001:IMMI2CT estFailed
IMMIndicatesfailureinLEDbus(BUS3).
Recoverable
No
Severity
Error
Serviceable
Yes
Automaticallynotifysupport
No
UserResponse
Performtheactionsmentionedoneatatimeandtrythetestaftereachaction:
1.Turnoffthesystemanddisconnectitfrompower.Waitfor45seconds.Reconnectittopower.
2.MakesurethatDSAandBMC/IMMareatthelatestlevel.
3.Runthetestagain.
4.Iffailureremains,referto"Troubleshootingbysymptom"inthesystem"InstallationandService
Guide"forthenextcorrectiveaction.
Relatedlinks
IBMSupportwebsite
LatestlevelofDSA
LatestlevelofBMC/IMM
166-905-001:IMMI2CT estFailed
IMMIndicatesfailureinPowerSupplybus(BUS4).
Recoverable
No
Severity
Error
Serviceable
Yes
Automaticallynotifysupport
No
UserResponse
Performtheactionsmentionedoneatatimeandtrythetestaftereachaction:
1.Turnoffthesystemanddisconnectitfrompower.Waitfor45seconds.Reconnectittopower.
2.MakesurethatDSAandBMC/IMMareatthelatestlevel.
3.Runthetestagain.
AppendixC.DSAdiagnostictestresults653