Mechanical installation
Standard devices in the power range 3 ... 22 kW
Mounting in "cold plate" technique
5
l
129
EDS84ASC552 EN 8.1
Ambient conditions
ƒ The rated data and the derating factors at increased temperature also apply to the
ambient temperature of the drive controllers.
ƒ Temperature at the cooling plate of the drive controller: max. 75 °C.
) Note!
Apply standard heat−conducting paste or heat−conducting foil onto cooler and
cooling plate before you bolt the controller onto the cooler.
StateLine, HighLine
8400GG106b
Fig. 5−33 Device dimensions
h b t h
1
h
2
b
1
t
1
g
1
g
2
[kW] [mm]
E84AVxxC3024xX0
3
270 174 141 318 366 140 128 6 5
E84AVxxC4024xXx
4
E84AVxxC5524xXx
5.5
E84AVxxC3024xB0
3
270 174 161 318 366 140 148 6 5
E84AVxxC4024xBx
4
E84AVxxC5524xBx
5.5