Mechanical installation
Standard devices in a power range of 0.25 ... 3 kW
Assembly in push−through technique (thermal separation)
5
l
99
EDS84ASC552 EN 8.1
StateLine, HighLine
8400GG105g
Fig. 5−8 Dimensions for mounting
a e d
1
d
2
d
3
d
4
c c
1
c
2
c
3
i j
11
j
21
[kW] [mm] [kg]
E84AVxxD2512xXx
0.25
75 170 10 10 85 80 12 6 6 90 0 > 95 > 95 1.4
E84AVxxD3712xXx
0.37
E84AVxxD3714xXx
0.37
75 221 8.5 12.5 110 105 12 6 6 90 0 > 95 > 95 1.9
E84AVxxD551xxXx
0.55
E84AVxxD751xxXx
0.75
E84AVxxD112xxXx
1.1
109 274 12.5 12.5 135 135 12 6 6 125 0 > 95 > 95 3.5
E84AVxxD152xxXx
1.5
E84AVxxD222xxXx
2.2
E84AVxxD2512xBx
0.25
75 170 10 10 85 80 12 6 6 90 0 > 95 > 95 1.5
E84AVxxD3712xBx
0.37
E84AVxxD3714xBx
0.37
75 221 8.5 12.5 110 105 12 6 6 90 0 > 95 > 95 2.0
E84AVxxD551xxBx
0.55
E84AVxxD751xxBx
0.75
E84AVxxD112xxBx
1.1
109 274 12.5 12.5 135 135 12 6 6 125 0 > 95 > 95 3.6
E84AVxxD152xxBx
1.5
E84AVxxD222xxBx
2.2