Technical data
TopLine C control terminals
Multi−encoder connection
4
l
85
EDS84ASC552 EN 8.1
X8 Pin
Description
EYF001... cable EYF002... cable
TTL 1 V
SS
1 V
SS
Hiperface
SSI
1 A A COS
n. c.
2 GND GND GND GND
3 B B Sin
n. c.
4 V
CC
V
CC
V
CC
U
S
5 Z Z +RS485 Data +
6
n. c. n. c. n. c. n. c.
7 −KTY −KTY −KTY
n. c.
8
n. c. n. c. n. c.
Clock +
9 /A /A Ref COS
n. c.
10
n. c. n. c. n. c. n. c.
11 /B /B Ref SIN
n. c.
12
n. c. n. c. n. c. n. c.
13 /Z /Z −RS485 Data −
14 +KTY +KTY +KTY
n. c.
9400SSP000X8
15
n. c. n. c. n. c.
Clock −
Setting the supply voltage
The supply voltage of the encoder must be adjusted depending on the cable length.
This value is adjusted via the "Encoder voltage" parameter, C00421.
Encoder U
r
Voltage setting [V] in C00421 for cable length [m]
Product key [V] 0 − 10 10 − 30 30 − 50 50 − 70 70 − 90 90 − 100 100 −150
TTL
IG2048−5V−T
5 ±5% 5.0 5.0 5.1 5.1 5.2 5.2 5.3
IG4096−5V−T
IK2048−5V−T
IK4096−5V−T
Sin/cos
IG1024−5V−V
5 ±5% 5.0 5.0 5.1 5.1 5.2 5.2 5.3
IG2048−5V−S
Sin/cos (Hiperface)
AM1024−8V−H
8
(7 ... 12)
8.0
Tab. 4−1
V
r
Rated voltage of the encoder
The values provided in Tab. 4−1 apply if Lenze system cables are used at typical ambient
temperatures.
Different cables, cable cross−sections, or extreme ambient temperatures may require
adaptation after another metrological measurement process.
Encoders (e.g. laser−based length measuring systems) must be externally supplied if their
supply must be increased.