Safety engineering 10
Certification
10.7 Certification
The certification of drivebased safety in the controllers of the 8400 series is based on the
following test fundamentals:
> EN ISO 138491
> EN 602041
> EN 618003
> IEC 61508, part 17
> EN 62061
> EN 6180051
> EN 6180052
The function of the safety unit meets the requirements of the following standards:
> Category 4 and PL e according to EN ISO 138491
– To comply with category 4, the external wiring and the cable monitoring must
meet the requirements of category 4.
– Ensure that short circuits cannot occur in the external wiring.
> SIL 3 according to IEC 61508
– The safety unit does not contribute to the probability of failure on demand (PFD)
and probability of failure per hour (PFH) of IEC 61508.